Bring the whole system into focus.

Closed ceilings, missing pathways and inconsistent outlet records turn a simple change into an investigation. Cabling quality depends on coordinated routes and verified links as much as on the category printed on a reel.

Build a traceable infrastructure from demarcation to rack, backbone and work area. Acceptance uses the agreed test method and documented results, giving future support teams a reliable starting point.

Explore the full scope

THE SERVICE CATALOGUE

Specific expertise. Practical deliverables.

20 distinct services within structured cabling & fiber optics. Select the tasks your project needs; scope, ownership and acceptance are agreed before delivery.

01

Structured cabling design

Plan outlets, telecommunications spaces and cable routes around the building layout and intended applications. Define counts, media and identification before installation so the physical network remains maintainable as occupancy changes.

Deliverable

Cabling drawings and outlet schedule.

02

Category 6 installation

Install approved Category 6 horizontal cabling with suitable pathways, bend control and termination practices. Agree the permanent-link or channel test requirement before work begins and record each completed link.

Deliverable

Labeled copper links and test results.

03

Category 6A installation

Deploy Category 6A cabling for the agreed channel and application requirements. Coordinate cable size, pathway fill, termination hardware and handling practices rather than assuming a higher category alone guarantees performance.

Deliverable

Certified links and as-built outlet map.

04

Fiber backbone installation

Install the approved single-mode or multimode backbone between telecommunications spaces. Coordinate route protection, fiber count and future capacity, with splice and patching locations defined in the design.

Deliverable

Backbone schedule and optical test records.

05

Fusion splicing

Join compatible optical fibers using appropriate preparation, cleaning and splice protection. Record fiber identification and the agreed verification results so each splice can be traced within the completed backbone.

Deliverable

Splice schedule and verification evidence.

06

Fiber termination

Terminate optical cables using the approved connector and enclosure system. Manage fiber protection, polarity and labeling so patching can be performed without confusing strands or exceeding physical limits.

Deliverable

Termination schedule and labeled enclosures.

07

OTDR testing

Use OTDR traces where appropriate to characterize optical events and help locate faults. Agree wavelengths, launch arrangements and reporting requirements; distinguish this evidence from end-to-end insertion-loss testing.

Deliverable

Trace files and interpreted event records.

08

Optical loss testing

Measure agreed end-to-end optical link loss with suitable test equipment and reference method. Compare results against the project loss budget and document fiber identification, wavelength and test direction.

Deliverable

Optical loss report and acceptance record.

09

Copper certification

Certify installed copper links to the agreed category and test configuration. Retain individual results with matching outlet identifiers, documenting failed links and remediation before final acceptance.

Deliverable

Native test files and summary report.

10

Patch-panel installation

Install approved panels and terminate cable groups in a documented sequence. Provide accessible management and durable labels so every outlet can be traced from room to telecommunications space.

Deliverable

Panel schedule and termination inspection.

11

Telecommunications outlet fit-out

Install data outlets with approved boxes, faceplates and port identification. Coordinate final positions with furniture, displays and other trades before closing walls or completing occupied-space finishes.

Deliverable

Outlet register and installation record.

12

Cable tray coordination

Plan and coordinate low-voltage cable support with building pathways and other services. Confirm the responsible trade, loading and access requirements before installation to avoid inaccessible or congested routes.

Deliverable

Pathway layout and coordination notes.

13

Conduit pathway coordination

Define containment routes and pull requirements for the agreed cabling. Coordinate with qualified installers and building requirements, documenting blocked or incomplete pathways before the cable installation starts.

Deliverable

Conduit requirements and readiness inspection.

14

Communications rack fit-out

Prepare racks with panels, cable management and agreed accessories for active equipment. Keep service loops and routing accessible so installation quality supports future maintenance and expansion.

Deliverable

Rack elevation and installed-accessory schedule.

15

Cable labeling systems

Apply a consistent identification scheme across outlets, panels, backbones and spaces. Match the physical labels to drawings and test records so a technician can trace a connection without guesswork.

Deliverable

Label schedule and identification standard.

16

Existing cabling audit

Inspect and trace selected existing links before reuse or upgrade. Identify media, termination condition and documentation gaps, with testing scoped to establish whether reuse meets the project requirement.

Deliverable

Reuse assessment and cable inventory.

17

Fiber fault localization

Investigate an optical connection using inspection and suitable measurements. Separate connector contamination, physical damage and routing issues, then propose a repair based on evidence rather than replacing an entire backbone automatically.

Deliverable

Fault findings and repair recommendation.

18

Cabling remediation

Repair or replace agreed nonconforming links and termination issues. Repeat the relevant acceptance tests and update records so remediated work does not remain disconnected from the original installation history.

Deliverable

Remediation log and replacement test results.

19

Demarcation extension

Extend approved carrier or building connectivity from the agreed handoff to the customer's equipment location. Confirm media, ownership boundaries and testing with the relevant provider before connecting services.

Deliverable

Demarcation route and handoff record.

20

Cabling handover documentation

Assemble outlet maps, panel schedules, fiber records and test evidence into an organized package. Reconcile identifiers across documents so the completed cabling can be supported and expanded consistently.

Deliverable

Editable as-builts and indexed certification pack.

Structured Cabling & Fiber Optics
FROM SYSTEM TO EXPERIENCE

The physical foundation of a connected building.

Build a traceable infrastructure from demarcation to rack, backbone and work area. Acceptance uses the agreed test method and documented results, giving future support teams a reliable starting point.

Follow the delivery process

TECHNICAL SCOPE

Clear interfaces.
Clear ownership.

Link category, test limits, warranty eligibility and specialist containment responsibilities are agreed before installation. No manufacturer programme status is implied.

Project applications

  • New construction
  • Office fit-outs
  • Campus backbones
  • Infrastructure remediation
Discuss your application

Delivery approach

A clear path from brief to handover

  1. 01

    Discover

    Agree the scope, users, premises and acceptance needs.

  2. 02

    Design

    Document the architecture, device schedules and dependencies.

  3. 03

    Coordinate

    Confirm materials, access and the resources assigned to the work.

  4. 04

    Deploy

    Implement the approved configuration and physical installation.

  5. 05

    Validate

    Test the actual workflows and record exceptions with owners.

  6. 06

    Support

    Transfer documentation and agree the operating responsibilities.

TECHNICAL HANDOVER

Make the result useful beyond installation.

Assemble outlet maps, panel schedules, fiber records and test evidence into an organized package. Reconcile identifiers across documents so the completed cabling can be supported and expanded consistently. Editable as-builts and indexed certification pack.

A traceable physical connection
Outlet identifierPanel scheduleTest result
One matching record in the as-built handover

YOUR QUESTIONS

Structured Cabling & Fiber Optics
explained.

Selection depends on the intended applications, channel length, environment and lifecycle goals. The design records the rationale and the agreed test requirement.

OTDR characterizes events; insertion-loss measurements address end-to-end loss. The project specifies the evidence appropriate to its acceptance requirements.

A scoped audit and appropriate testing can establish reuse suitability. Unidentified or untested links are not assumed to meet the new requirement.

The agreed handover can include native tester results alongside readable summaries, matched to the final outlet and backbone identifiers.

Containment and any regulated work are assigned during planning. FBT coordinates route requirements and verifies readiness for the cabling scope.

Before walls and ceilings close. Early review of outlets, equipment rooms and pathways reduces changes after finishes are complete.

A fault investigation can identify whether a connector, splice or cable section needs remediation before a repair scope is selected.

The agreed naming standard links outlets, panels, fibers, drawings and test results so support staff can trace each commissioned connection.